GOSSEN Mueller & Weigert 49
Order Example:
Moving-Coil Voltmeter for AC, 96 x 96 mm,
240˚ Scale, 0 ... 500 V
Order No.: 1605W DC500
Front Dim., mm
48 x 48
72 x 72 96 x 96
144 x 144
Type
V-Pq48-250 V-Pq72-250
V-Pq
96-250
Pq144-250
Order no.
1668W
1602W 1605W
1621W
Meas. Input−Alternating Current Connection
direct
1 A/1.5 A/2.5 A/4 A CC1/1.5/2.5/4 ++++
at transformer sec.: 1 A BE10 ++++
at transformer sec.: 5 A BE11 ++++
at trans. sec.: 1 A BE22 ++++
at trans. sec.: 5 A BE23 ++++
Meas. Input−Alternating Voltage Connection
direct
2.5/4/6/10 V DC2.5
15/25/40/60 V to
100/150/250/300/400/500/600 V DC600 ++++
at transformer sec.: 100 V BF12 ++++
at transformer sec.: 110 V BF15 ++++
at trans. sec.: 100 V BF25 ++++
at trans. sec.: 110 V BF26 ++++
Overload Capacity none –
++++
2-fold with integrated saturation transformer BU20 – – + +
2-fold with separate saturation transformer BU21 + + – –
Attention: Saturation transformer only possible
with connection via current transformer (order
no. BE 10 and BE 11), and with nominal
frequencies 50 Hz or 60 Hz.
Scale Characteristics proportional to current − ++++
per curve SD6 ++++
Applications standard − ++++
conditionally tropic-proof LB1 + + ++
Protection standard − ++++
front panel: IP 54, terminals: IP00 LH21 ++++
Resistance to Vibration /
standard − ++++
Marine Applications
vibr. resistance: 2.5 g, shock resistance: 30 g LN56 ++++
marine applications, German Lloyds LN2 ++++
Bezel dull black − ++++
dull gray, RAL 7037 MA11 ++++
Glass Faceplate standard −
++++
anti-glare MG1 ++++
Housing standard − ++++
sheet metal housing with cone-head rivets ML4 – + + –
1
)
Fasteners standard −
++++
type S screw clamp MN14 + –
1)
–
1)
–
4 leaf springs MN1 + + + –
Contact Protection none − ++++
full contact protection VB2 ++++
individual contact protection VB1 ++++
Identification none − ++++
at rear: ............ MZ998 ... ++++
Scale Inscription none − ++++
(Latin lettering) ≤15 characters in German SM991 ... ++++
≤15 characters in other language SM993 ... ++++
Additional Numberings none − ++++
2
nd
set of numberings, black: ... SK992 ... ++++
Red Marker (RAL 2002) none − ++++
red marker at: ... ST991 ... ++++
Order Number Instructions:
• Select one model each for order numbers with the same sequence of letters.
1) Standard model
• No additional entries are required for standard models (identified with bold typeface and “−” in order no. column).
• An entry with “....” in the order no. column means that the order number must be supplemented with written text.
➡
➡
+
1.2-fold
overload
1.2-fold
overload
Square Panel Meters for
Alternating Current or Alternating Voltage, 240˚ Scale
Order Information
Code: B0
Komentáře k této Příručce