Order Example:
Moving-Coil Voltmeter, 96 x 96 mm,
240˚ Scale, 0 ... 40 V Direct Voltage
Order No. 1605P DC40
Front Dim., mm 48 x 48 72 x 72 96 x 96 144 x 144
Type V-Pq48-250 V-Pq72-250 V-Pq96-250 Pq144-250
Order no.
1668P 1602P 1605P 1621P
Meas. InputDirect Current Connection
Zero Point left
center
BC2
++
++
as desired
BC20
++
++
direct 1 mA/5 mA/10 mA
CB1/5/10
++++
20 mA CB20 + + + +
1 A/1.5 A/2.5 A/4 A CC1/1.5/2.5/4 + + + +
6 A/10 A CC6/10 + + +
15 A/25 A/40 A CC15/25/40 + + +
mech. suppressed 4 ... 20 mA BC10 + + + +
left at shunt resistor .../60 mV BE3 + + + +
at shunt resistor .../150 mV BE4 + + + +
Meas. InputDirect Voltage Connection
Zero Point left
center BC2 ++
++
as desired
BC20
++
++
direct 1/1.5/2.5/3/4/6/10 V DC1
15/25/40/60 V
to
100/150/250/400/500/600 V
DC600 +
+++
Scale Characteristics proportional to current
++++
per curve SD6 + + + +
Applications standard
++++
conditionally tropic-proof LB1 + + + +
Protection standard
++++
front panel: IP 54, terminals: IP00 LH21 + + + +
Resistance to Vibration / standard
++++
Marine Applications vibration resistance: 2.5 g, shock resistance: 30 g
LN56
++++
marine applications, German Lloyds
LN2
++++
Bezel dull black
++++
dull gray, RAL 7037 MA11 + + + +
Glass Faceplate standard
++++
anti-glare MG1 + + + +
Housing standard
++++
sheet metal housing with cone-head rivets ML4 ++
1
)
Fasteners standard
++++
type S screw clamp MN14 +
1
)–
1
)–
4 leaf springs MN1 + + +
Contact Protection none
++++
full contact protection VB2 + + + +
individual contact protection
2
)
VB1
++++
Identification none
++++
at rear: ............ MZ998 ... + + + +
Scale Inscription none
++++
(Latin lettering) 15 characters in German SM991 ... + + + +
15 characters in other language SM993 ... + + + +
Additional Numberings none
++++
2
nd
set of numberings, black: ... SK992 ... + + + +
Red Marker (RAL 2002) none
++++
red marker at: ... ST991 ... + + + +
Order Number Instructions:
Select one model each for order numbers with the same sequence of letters.
1) Standard model
2) Voltmeters and ammeters 4A
No add. entries are required for std. models (identified with bold type and “in order no. column).