12 GOSSEN Mueller & Weigert
Moving-Coil Movement with Rectifier, 90° Scale
Narrow Bezel per DIN 43718
Front Dimensions 48 x 48 mm 72 x 72 mm 96 x 96 mm 144 x 144 mm
Type DG 48 DG 72 DG 96 DG 144
Scale Length 37 mm 63 mm 97 mm 150 mm
Accuracy Class 1.5 1.5 1.5 1.5
Weight (standard model), Max. 0.12 kg 0.2 kg 0.28 kg 0.49 kg
Operating Voltage, Max. 300 V 600 V 600 V 600 V
Test Voltage 2.2 kV 3.25 kV 3.25 kV 3.25 kV
Front Housing Panel Protection IP 52 IP 52 IP 52 IP 52
In preparation
Type DG 96
Square Panel Meters
for Alternating Current 40... 45 ... 65 ... 1000 Hz or
Alternating Voltage 40... 45 ... 65
... 10000 Hz
Technical Data
Description
Analog Panel Meter with Core-Magnet Moving-Coil Movement
and Spring-Loaded Pivot Bearings and Rectifier
Internal Resistance / Power Consumption
Reference Conditions
Nominal Range of Use Limits
Dimensions
With separate matching transformers for ammeters with front
panel dimensions of 48 x 48 mm: L x W x H = 80 x 55 x 31 mm
Dimensional Drawing (upon request) 1303A1839H0
Dimensions
Display
Scale Graduation Coarse-fine
Pointer Beam pointer with knife-edge
Mechanical Design
Housing Material Polycarbonate, self-extinguishing and drip-proof per UL94V-0
or sheet metal housing for front panel dimensions of
72 x 72 mm and 96 x 96 mm as option.
Mounting Fasteners Standard: S type screw clamp, except:
screw spindle for 144 x 144 mm panel meters
alternative: see next page
Scale Interchangeable scales
➲ Scales may only be replaced under voltage-free conditions!
Replaceable Bezels and glass faceplate
➲ May only be replaced under voltage-free conditions!
Terminals M4 screw terminals with self-lifting terminal clips. Screws
can be turned with cross-head or standard screw drivers.
Terminal Designation “11” and “12”, except:
“17” and “18” for 144 x 144 mm panel meters
Contact Protection Finger-safe full cover included
Measuring Input Internal Resistance Power
Consumption
Connection
to transformer current approx. 0.15 VA
direct or to transformer voltage 900 Ω/V ±10%
Reference Quantities Reference Conditions
Ambient Temperature 23°C ± 2°C
Position of Use control panel vertical ±1°
Frequency 45 ... 65 Hz
Waveshape sine, distortion factor ≤1%
Other DIN EN 60051
Frequency for alternating current, 40 ... 1000 Hz
for alternating voltage, 40 ... 10000 Hz
Front in mm Nominal Dimensions, mm Cutout Dimensions, mm Installation Depth Including Terminals (t), mm Installation Depth Incl. Full Cover (f), mm
a
1
x a
2
h
I
1
x I
2
M4
48 x 48 48 x 48 5 45
+0.6
x 45
+0.6
54 62.5
72 x 72 72 x 72 5 68
+0.7
x 68
+0.7
54 62.5
96 x 96 96 x 96 5 92
+0.8
x 92
+0.8
54 62.5
144 x 144 144 x 144 8 138
+1
x 138
+1
54 62.5
Komentáře k této Příručce