40 GOSSEN Mueller & Weigert
Moving-Coil Movement, 240° Scale
Narrow Bezel per DIN 43718, Dull Black
Front Dimensions 48 x 48 mm 72 x 72 mm 96 x 96 mm 144 x 144 mm
Type V-Pq 48-250 V-Pq 72-250 V-Pq 96-250 Pq 144-250
Scale Length 73 mm 113 mm 151 mm 235 mm
Accuracy Class 1.5 1.5 1.5 1.5
Weight in kg, Approx. 0.16 0.2 0.25 0.65
Nominal Insulation Voltage 660 V 1000 V 1000 V 660 V
Test Voltage 2 kV 3 kV 3 kV 2 kV
Front Housing-Panel Protection IP 52 IP 52 IP 52 IP 52
Fasteners (see next page) leaf spring type S type S type G
Housing Material polycarbonate polycarbonate polycarbonate sheet metal
Interchangeable Scale yes yes yes no
Front Dim. in mm Nominal Dimensions, mm Cutout, mm Installation Depth, mm Ter minals
a
1
x a
2
h
I
1
x I
2
(t)
≤4 A
M4
> 4 A
M6
48 x 48 48 x 48 5 45
+0.6
x 45
+0.6
43.5 12.5 –
72 x 72 72 x 72 5 68
+0.7
x 68
+0.7
43.5 12.5 17
96 x 96 96 x 96 5 92
+0.8
x 92
+0.8
43.5 12.5 18
144 x 144 144 x 144 8 138
+1
x 138
+1
44.5 12.5 18
Type V-Pq 96-250
Square Panel Meters
for Direct Current or Direct Voltage
Technical Data
Description
Analog Panel Meter with Moving-Coil Movement
Reference Conditions
Internal Resistance / Voltage Drop / Power Consumption
1
)
1) Indicated internal resistance is only valid for instruments with standard accuracy classes.
Please inquire regarding internal resistance (Ri) for moving-coil indicators with mechanical zero point at any desired
scale value.
Dimensions
Display
Scale Graduation Coarse-fine
Pointer Beam pointer with knife-edge
Mechanical Design
Housing Material Polycarbonate, self-extinguishing and drip-proof per UL94V-0
or sheet metal housing (see above).
Sheet metal housing for V-Pq 72-250 and V-Pq 96-250
available as option.
Replaceable Glass faceplate, bezel and scale (no interchangeable scales for
front dimensions 144 x 144 mm).
Terminals M4 (voltmeters and ammeters ≤ 4 A) or
M6 (ammeters > 4 A).
M4 screw terminals with self-lifting terminal clips. Screws can
be turned with cross-head or standard screw drivers.
Contact Protection Available as option
Reference Quantities Reference Condition
Ambient Temperature 23°C ±2°C
Position of Use control panel vertical ± 1°
Other DIN EN 60051
Measuring Range Ri
1 mA 337 Ω ±20%
5 mA 16.3 Ω ±20%
10 mA 3 Ω ±30%
20 mA 5 Ω ±30%
4 ... 20 mA 6.5 Ω ±30%
≥ 1 A
Connection to shunt
Voltage drop 150 mV ±20%
Power consumption 10 mA ±20%
Lead resistance 0.06 Ω ±20%
≥1 V 1000 Ω /V ±20%
2) Individual contact protection
3) Full contact protection (22 mm only for 48 x 48 mm front dimensions)
a
1
x a
2
l
1
x l
2
h
t
e
22...23.5
3)
17.5
2)