GOSSEN Mueller & Weigert 27
Order Example:
Power Factor Meter for 3-Wire System with Balanced Load,
5 A Secondary Transformer Terminal, 500 V Nominal Voltage
Order No.: 3200H AB22 BE11 IL 350
Front Dim. in mm 96 x 96 144 x 144
Type LF 96 LF 144
Order no.
3200H 3250H
(in preparation)
System Type / Power Type Nominal Voltage
Single Phase Alternating Current AB21
++
100 VAC IL 310 ++
110 VAC IL 311 ++
220 ... 240 VAC IL 728 ++
3-Wire System, Balanced Load AB22 ++
100 VAC IL 310 ++
110 VAC IL 311 ++
380 ... 400 VAC IL 727 ++
415 ... 440 VAC IL 730 ++
500 VAC IL 350 ++
Current Path Terminal at transformer sec.: 1 A BE10 ++
at transformer sec.: 5 A BE11 ++
Position of Use standard ++
0 ... 45 degrees from horizontal (bonded glass faceplate) LA11 ++
46 ... 89 degrees from horizontal (bonded glass faceplate) LA12 ++
91 ... 135 degrees from horizontal LA13 ++
Applications standard ++
conditionally tropic-proof, climatic category 3 LB4 ++
Protection standard
++
front panel: IP 54, terminals: IP00
LH21 ++
Resistance To Vibration / standard ++
Marine Applications vibration resistance: 2.5 g, shock resistance: 30 g LN56 ++
marine applications, German Lloyds LN8 ++
Bezel dull black ++
dull grey, RAL 7037 MA11 ++
Glass Faceplate standard ++
anti-glare MG1 ++
anti-glare, with red adjustable set pointer MG98 ++
Housing and Fasteners standard ++
sheet metal housing with type S screw clamp ML7 +
sheet metal housing with type B screw clamp ML8
+
polycarbonate housing with 2 leaf springs ML9
+
polycarbonate housing with 4 leaf springs ML11
+
polycarbonate housing with Subklew fasteners ML10
+
Identification none
+
at rear: ............ MZ998 ... ++
Scale Inscription none ++
(Latin lettering) 22 characters, 1 line: .......... SM902 ... ++
37 characters, 2 lines: 1
st
line (15 characters): ..., 2
nd
line (22 characters): ... SM911 ... ++
Red Marker (RAL 2002) none ++
red marker at: ... ST981 ... ++
Order Number Instructions:
Select one model each for order numbers with the same sequence of letters.
No additional entries are required for standard models (identified with bold typeface and “” in the order no. column).
An entry with “....” in the order no. column means that the order number must be supplemented with written text.
Square Panel Meters
for Power Factor
Order Information
Code: B0
Zobrazit stránku 26