24 GOSSEN Mueller & Weigert
Order Example:
Active Power Meter for 3-Wire System with Unbalanced Load,
100/5 A Transformer Ratio, 400 V Nominal Voltage, Measuring Range:
0 ... 60 kW
Order No.: 3200D AB4 BE11 CG100 IL340 NB: 0 ... 60 kW
Front Dim. in mm 96 x 96 144 x 144
Type LM 96 LM 144
Order no.
3200D 3250D
(in preparation)
System Type / Power Type Voltage Path Terminal
2-Wire System
Active Power, Single Phase AC AB1
++
at transformer sec.: 100 V primary voltage: ... V BF12 DG ... ++
primary voltage: ... kV BF12 DH ... ++
at transformer sec.: 110 V primary voltage: ... V BF15 DG ... ++
primary voltage: ... kV BF15 DH ... ++
direct, 220 VAC IL322 − ++
direct, 230 VAC IL323 − ++
direct, 240 VAC IL324 − ++
Reactive Power, Single Phase AC AB11 ++
direct, 220 VAC IL322 − ++
direct, 230 VAC IL323 − ++
direct, 240 VAC IL324 − ++
3-Wire System
Active Power, 3-Wire, Balanced Load AB2
++
Reactive Power, 3-Wire, Balanced Load AB12 ++
Active Power, 3-Wire, Unbalanced Load AB4 ++
Reactive Power, 3-Wire, Unbalanced Load AB14 ++
at transformer sec.: 100 V primary voltage: ... V BF12 DG ... ++
primary voltage: ... kV BF12 DH ... ++
at transformer sec.: 110 V primary voltage: ... V BF15 DG ... ++
primary voltage: ... kV BF15 DH ... ++
direct, 380 VAC IL338 − ++
direct, 400 VAC IL340 − ++
direct, 415 VAC IL661 − ++
direct, 440 VAC IL344 − ++
direct, 500 VAC IL350 − ++
4-Wire System
Active Power, 4-Wire, Balanced Load AB5
++
Reactive Power, 4-Wire, Balanced Load AB15 ++
Active Power, 4-Wire, Unbalanced Load AB6 ++
Reactive Power, 4-Wire, Unbalanced Load AB16 ++
at transformer sec.: 100 V primary voltage: ... V BF12 DG ... ++
primary voltage: ... kV BF12 DH ... ++
at transformer sec.: 110 V primary voltage: ... V BF15 DG ... ++
primary voltage: ... kV BF15 DH ... ++
direct, 220/380 VAC IL718 − ++
direct, 230/400 VAC IL723 − ++
direct, 240/415 VAC IL721 − ++
direct, 254/440 VAC IL722 − ++
direct, 277/480 VAC IL724 − ++
Current Path Terminal at transformer sec.: 1 A primary current: ... A BE10 CG ... ++
primary current: ... kA BE10 CH ... ++
at transformer sec.: 5 A primary current: ... A BE11 CG ... ++
primary current: ... kA BE11 CH ... ++
Zero Point left −−− ++
center BC2 −− ++
10% of positive upper value BC6 −− ++
Upper Measuring Range Value (adjustable from 0.5 to 1.2 times apparent power) NB ... −− ++
Order Number Instructions:
• Select one model each for order numbers with the same sequence of letters.
• No additional entries are required for standard models (identified with bold typeface and “−” in the order no. column).
• An entry with “....” in the order no. column means that the order number must be supplemented with written text.
➡
Square Panel Meters
for Active Power or Reactive Power
Order Information
Code: B0