IIMMPPOORRTTAANNTT!!
Never use this wire to drive anything but a relay or a low-current input! The tran-
sistorized output can only supply 200 mA of current. Connecting directly to a solenoid, motor,
or other high-current device will cause it to fail.
Before connecting this wire, remove the supplied fuse. Connect to the positive battery terminal or the constant
12V supply to the ignition switch.
NNOOTTEE::
Always use a fuse within 12 inches of the point you obtain (+)12V power. Do not use the
15A fuse in the harness for this purpose. This fuse protects the module itself.
Connect this to the red wire of the siren. Connect the black wire of the siren to (-) chassis ground, preferably at
the same point you connect the control module’s black ground wire.
Connect this wire to an ignition source. This input must show (+)12V with the key in run position and during
cranking. Make sure that this wire cannot be shorted to the chassis at any point. This wire will report Zone 5.
HH11//44 YYEELLLLOOWW ((++)) iiggnniittiioonn iinnppuutt,, zzoonnee 55
BROWN H1/3
(+) 12V SIREN OUTPUT
RED
BLACK
HH11//33 BBRROOWWNN ((++)) ssiirreenn oouuttppuutt
HH11//22 RREEDD ((++))1122VV ccoonnssttaanntt ppoowweerr iinnppuutt
H1/1 RED/WHITE
(+) 12V CONSTANT FUSED
85
86
30
87
87A
(+) 12V IF (+) SWITCHED
(-) GROUND IF (-) SWITCHED
SWITCHED TRUNK
RELEASE WIRE