Last Start Diagnostics:
The system holds in memory the reason for the most recent
remote start activation. This diagnostic report must be recalled
using the following operation:
1. Turn the ignition ON and then OFF in less than 5 seconds
2. Within 5 seconds press and release the Momentary
Switch
3. After 2 seconds the LED will flash/pause and repeat 5
times to indicate the cause of the most recent remote
start activation.
4. Count the LED flashes and consult the Last Start
Diagnostic Chart
Last Start Diagnostic Chart
LED
Flashes
Description
1 The Remote Starter has not been activated since the main power
was connected
2 No Diagnostic
3 The Activation Input wire was used to activate the Remote starter
4 Low temperature activated the Remote Starter in Vacation Mode
5 Low battery voltage activated the Remote Starter in Vacation Mode
6 No Diagnostics
7 Daily Start activated the Remote Starter