10
©
2002
Directed Electronics, Inc.
H1/6 BLUE (-) Multiplexed Trigger Input, Zone 1 and Trunk Icon
This input will respond to a negative input with a WarnAway
®
or instant trigger. It is ideal for hood
and trunk pins and will report on Zone 1. It can also be used with Directed dual-stage sensors. The
H1/6 BLUE WarnAway
®
or instant trigger wire can also be used to shunt sensors during operation of
auxiliary channels or remote start. (See Bypassing Sensor Inputs section of this guide.)
H1/7 VIOLET (+) Door Trigger Input, Zone 3 and Door Icon
This type of dome circuit is used in many Ford products. Connect the VIOLET wire to a wire that
shows (+)12V when any door is opened. This wire will report Zone 3.
NOTE: If using a door trigger wire that has a delay, Advanced Menu 2, feature 6, or the 998T
Bitwriter can be used to turn Bypass Notification off.
H1/8 BLACK (-) Chassis Ground Connection
Connect this wire to a clean, paint-free sheet metal location (driver kick panel) using a factory bolt
that DOES NOT have any vehicle component grounds attached to it. A screw should only be used
when in conjunction with a two-sided lock washer. Under dash brackets and door sheet metal are
not acceptable ground points. It is recommended that all security components be grounded at the
same location.