Directed Electronics Valet 561T Instalační příručka Strana 14

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 39
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 13
1144
© 2005 Directed Electronics—all rights reserved
This input comes from the factory set to 2 activation pulses. This means that it is necessary to have 2 consecu-
tive 12V pulses on the white/blue wire for the remote start to activate or to deactivate. The same holds true for
the remote control activation when set to a two pulse setting it is necessary to press the button twice for
the remote start to activate or deactivate.
NNOOTTEE::
When the activation pulse count can be programmed to 1, 2, or 3 pulses when changed it
will affect both activation inputs; the White/Red wire and the remote control activation.
When the system receives the code controlling Channel 2, for longer than 1.5 seconds, the RED/WHITE wire will
supply an output as long as the transmission continues. This is often used to operate a trunk/hatch release or
other relay-driven function.
IIMMPPOORRTTAANNTT!!
Never use this wire to drive anything except a relay or low-current input! The transistorized output
can only supply 200 mA of current. Connecting directly to a solenoid, motor, or other high-current device will
cause it to fail.
HH11//77 RREEDD//WWHHIITTEE CChhaannnneell 22,, ((--)) 220000 mmAA oouuttppuutt