© 1999 Directed Electronics, Inc. N381 9/99
H1/8 BLACK
(-) chassis ground connection: Connect this wire to bare metal, preferably with a factory bolt rather
than your own screw. Screws tend to either strip or loosen with time. We recommend grounding all your compo-
nents, including the siren, to the same point in the vehicle.
H1/9 YELLOW
(+) ignition input: Connect this wire to the +12V ignition wire. This wire must show +12V with the key
in run and crank position. Take care to insure that this wire cannot be shorted to the chassis at any point.
H1/10 BROWN
(+) siren output: Connect this to the RED wire of the Revenger
®
siren. Connect the BLACK wire of the
siren to (-) chassis ground, preferably at the same point you connect the control module’s BLACK ground wire.
H1/11 RED
(+)12V constant power input: Before connecting this wire, remove the supplied fuse. Connect to the
battery positive terminal or the constant 12V supply to the ignition switch.
NOTE: Always use a fuse within 12 inches of the point you obtain (+)12V. Do not use the 15A fuse in the har-
ness for this purpose. This fuse protects the module itself.
H1/12 RED/WHITE
high current output from on-board Channel Two (trunk release) relay: Whenever the button(s)
controlling Channel Two is pressed for 1.5 seconds, the on-board relay is activated and will stay activated as long
as the transmission continues. This relay is often used for trunk release. The relay can drive circuits up to 20
amperes.The polarity of this output is determined by the connection of the input wire (H2/A) in the Door Lock Harness.
NOTE: If the input wire (H2/A) is not connected, there will be no output from the relay when it is activated.
Relay Harness, 8-pin harness
H2/A RED/WHITE
input to on-board Channel Two (trunk release) relay: This wire is used to supply voltage to the
output (H1/12). If you want a positive output on H1/12, connect this wire to +12V. Always fuse appropriately. If a
negative output is desired, connect this wire to chassis ground.
H2/B BLACK/WHITE
input to domelight supervision relay: This wire determines what the output polarity of H1/4
will be. If the door pin circuit is negative, connect to chassis ground. If the door circuit is positive, connect to a fused
12V source.
H2/C - H2/H POWER DOOR LOCKS
The system has door lock relays on-board, and can directly interface with
most electric power door lock systems drawing 30 amps or less. It can also drive aftermarket actuators directly.
(Some vehicles require that an aftermarket actuator be added to the driver’s door to allow system control, see Type
D wiring).